VK2 volume flow controller
Volume flow controllers & volume flow limiter

VK2 volume flow controller

Mechanical constant volume flow controllers VK2 for use in rectangular air ducts for supply air and exhaust air applications. They automatically maintain the set volume flow at a constant level with high control accuracy. The volume flow setpoint can be preset at the factory. Optionally available acoustic insulation provides thermal insulation and reduces sound radiation.

Technical details

  • Suitable for controlling constant volume flows for supply air and exhaust air applications
  • Very high control accuracy
  • Presetting of the volume flow setpoint possible
  • Manual or actuator-driven adjustment available
  • Position-independent
  • Maintenance-free design
  • Environmental product declaration (EPD)
  • Hygiene certificate

Declarations & proofs

Environmental Product Declaration (EPD)
Hygiene certificate

Product details

Mechanical volume flow controllers VK2 are suitable for the constant control of supply air and exhaust air in ventilation and air conditioning systems. The square casing with nominal sizes from 200 mm x 100 mm to 600 mm x 300 mm (W x H) and the control mechanism are made of galvanized sheet steel. VK2 volume flow controllers are maintenance-free and operate in any position.

Setting the VK2 volume flow controller

The volume flow setpoint is specified by means of a setting device via a rotary pointer and scale. The volume flow is set manually using a locking device or, alternatively, by motor.

Control accuracy and volume flow range

The VK2 volume flow controllers operate without external energy. They maintain the set volume flow automatically and constantly with very high control accuracy in the specified pressure range with a deviation of approximately ±5% to ±15% from the volume flow setpoint. The volume flow range is between Vmin=200 m³/h and Vmax= 7,000 m³/h, the pressure range between 50 Pa and 1,000 Pa.

Product markings

VK2 volume flow controllers have a hygiene certificate from an independent testing institute and an environmental product declaration (EPD).

Options

  • Actuator-driven adjustment of the volume flow setpoint. Depending on the selected actuator, two setpoints or any intermediate values are possible.
  • Acoustic insulation provides thermal insulation and reduces sound radiation.
  • SKB-V duct silencer (length 1500 mm) for reducing flow noise in the ventilation duct

Technical specifications

Width
  • 200 mm
  • 300 mm
  • 400 mm
  • 500 mm
  • 600 mm
Height
  • 100 mm
  • 150 mm
  • 200 mm
  • 250 mm
  • 300 mm
Acoustic insulation
  • Without acoustic insulation
  • With acoustic insulation

Product pictures

VK2 volume flow controller turned halfway from the front to the left
VK2 volume flow controller viewed from the side
VK2 volume flow controller, turned halfway from behind to the right
VK2 volume flow controller from behind
VK2 volume flow controller, turned halfway to the left from behind
VK2 volume flow controller viewed from the side
VK2 volume flow controller turned halfway from the front to the right
VK2 volume flow controller from the front
VK2 volume flow controller turned halfway from the front to the left with acoustic insulation
VK2 volume flow controller turned halfway from the front to the left with actuator
VK2 volume flow controller turned halfway from the front to the left, with acoustic insulation and actuator